Fuel Conversion Procedure
1. Turn off gas supply to stove.
2. Remove the stove Top Plate.
3. Disengage the two Glass Frame Latches and lift the
glass panel frame up and out of the stove. See illustra-
tion on page 5.
4. If installed, remove the Embers and Log Set using care
not to damage the fragile log parts.
5. Lift out the Burner Skirt.
6. Reach under the stove and loosen the Air Shutter wing-
nut. Push the shutter stem back to ease burner removal.
See fig. 23.
7. Lift out the Burner Plate with removal of four screws
from the firebox floor. See fig. 24.
8. Change the Burner Injector. See fig. 25. Using a 1/2" open
end wrench or deep-well socket remove the burner ori-
fice from its brass elbow housing and replace with the
appropriate orifice supplied in the kit.
9. LP CONVERSION ONLY:
A) Install the stop screw into the air shutter plate. See
fig. 25.
10. CHANGE THE INTEGRATED DUAL-FUEL PILOT ORIFICE:
Use the 7/16" wrench to just loosen the pilot head
enough to push in the adjustment slide. See fig. 26.
LP : push tab to left (red dot exposed on slide).
NG: push tab to right
11. Replace the Burner Plate. Engage the burner tube with
the Air Shutter assembly. Be sure the burner is level and
secure it to the four support brackets with the screws
previously removed.
12. Replace the Valve Regulator. Using a Torx T-20 screw-
driver, remove the two screws from the front of the
regulator. Remove the regulator components and
replace with the one from the conversion kit. See fig. 27.
13. Install the identification labels to the stove so that they
can be seen by any person who may be servicing the
stove.
Label A: apply to back of stove
Label B: apply to the rating plate attached to the back of
the stove.
Small Conversion Label: apply to valve.
14. Reassemble the stove, apply gas to the system and
check for leaks using a soapy water solution or gas
detector.
NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.
Figure 24. Remove four sheet metal screws to lift burner
out of the firebox.
Figure 25. Burner injector
and LP stop screw.
Figure 27. Manual Regulator replacement.
139495_Rev_C GF 300 DV IPI 9/11/12
Figure 26. Integrated
dual-fuel pilot orifice- LP
position shown.
LP