Specifications

Input Rates
Natural Gas
32,000 BTU/hr. maximum input
18,000 BTU/hr. minimum input
Propane
32,000 BTU/hr. maximum input
16,000 BTU/hr. minimum input
Inlet Pressure:
MIN
Natural Gas:
5.0 WC (1.24 kPa)
Propane:
12.0 WC (2.99 kPa) 14.9 WC (3.71 kPa)
Manifold Pressure:
Natural Gas:
1.2 WC (.30 kPa)
Propane:
2.9 WC (.722 kPa)
Piezo Ignitor / Standing Pilot
Suggested Tools for
Installation and Service
• External regulator (for Propane only)
• Piping which complies with local code
• Manual shutoff valve (T-Handle in Massachusetts)
• Sediment trap - if required by code
• Tee joint
• Pipe wrench
• Pipe sealant
• 10 mm open end wrench
• 1/2", 7/16" open end wrench or deep socket
• Phillips head screwdriver
• Flat head screwdriver
• 1/4" nut driver
• 4 mm allen wrench
• Gloves
• Safety glasses
• Torx T20 screwdriver
• Leak test solution
• Reciprocating Saw
• Power Drill
4
MAX
7.0 WC (1.74 kPa)
MIN
MAX
3.8 WC (.95 kPa)
11.0 WC (2.74 kPa)
Specifications
26 1/2"
673 mm
13"
330 mm
19 5/8"
500 mm
19 1/2"
495 mm
*For height with 6" Legs, subtract 2 1/4"
28 1/2"
724 mm
26 1/2"
673 mm
C L
28 1/2"*
724 mm
25 1/2"*
647 mm
29"
737 mm