6. Adding refrigerant

If the connecting pipe is longer than 7m, add refrigerant as needed. Add amount
A= (Lm-7m) x 50g/m.
(A = amount of added refrigerant; L = the length of connecting pipe)
Exhaust the air as the above-
mentioned method.
Screw the gas shut-off valve to
close, connect charging hose(low
pressure) to the service valve
and then open gas shut-off valve
again.
Connect the refrigerant bottle
to the charging hose and then
convert it.
Fill in liquid refrigerant as the
above table.
Disconnect the manifold gauge
after turning off the shut-off
valve, and then open gas shut-
off valve again.
Tighten nuts and caps of
each valve.