Route of pipe
If pipe comes out of the right side of the
indoor unit, cut part "1" of the unit;
If pipe comes out of the lower-right side of
the indoor unit, cut part "2" of the unit;
If pipe comes out of the left side of the
indoor unit, cut part" 3" of the unit.
Refit of drain hose
If pipe comes out of the left side of the indoor
unit, the drain hose must be refitted, otherwise
water leakage may occur.
Readjustment methods: Interchange the position
of drain hose and drain rubber plug.
Clearance is not allowed after refit, it would lead
to water leakage.
5. Attaching the Indoor unit to the mounting plate
Let the pipe go through the hole you have made in
the wall and attach the indoor unit to the mounting
plate. Press the rib of indoor unit inside the hook of

the mounting plate.