LINE LENGTH:
90 -
94
Selects the maximum print line length expressed
in numper of characters at 10 cpi.
PRINTER REPLY SYNCRONIZED:
-
Y
DSR management during a transmission
STATUS REQUEST: NO WAIT
-
WAIT
Determines the timing of the status reply upon
reception of an ESC j command. By selecting
NO WAIT, the reply will be provided as soon as
possible and simultaneously with the execution
of a print job or paper movements. By selecting
WAIT, the status reply will be provided at the
end of the print job.
(if the Horizontal Magnetic devicelMlCR is present)
OPTION HORIZONTAL MSRW
This message warns that the option is installed.
There is no selection to be made, and the next
option available is printed right after it. If the
Horizontal magnetic device1MICR option is
present, the caption "+MICRN will appear next to
"MSRW.
STANDARD: DINIISO
-
ANSI
-
ISM 3604
Sets the magnetic standard.
(when) IBM 3604
END-SENTINEL:
C
-
F
Sets the end-sentinel code.
DISPLACEMENT: STANDARD + l 0 +20 Defines the position of the magnetic stripe.
DUPLICATE:
N
-
Y
Selects field duplication or not.
DOUBLE FIELD CHECK: N
-
Y
Selects double field check or not
RETRY: 3
-
1
Defines the read attempts.
STRIPE HANDLING: NORMAL
-
FAST
Defines normal or fast magnetic stripe reading.
When Normal is selected, at each magnetic
stripe read or write operation a savings book
length measurement is performed so as to
determine the exact position of the stripe.
When Fast is selected, the length of the
savings book is measured randomly with the
procedure explained in the specific chapter;
savings book measurements are not made
during stripe readlwrites thus speedi~g stripe
management.
Y
100250-4
Service Manual
4-1 1

Hide quick links: