Jøtul C 350 Winterport
Chimney Connection
This insert must be connected to a code-approved
masonry chimney or listed factory-built fireplace
chimney with a direct (positive) flue connector into
the first chimney liner section. The chimney size
should not be less than nor more than three times
greater than the cross-sectional area of the flue
collar.
The optional Jøtul Draw-Down Adaptor Kit
156073 is available to ease connection of the
chimney liner with the flue collar.
A positive connection must be made between the
fireplace insert and the chimney by one of the
following approved methods.
U U U U U .S .S .S .S .S. . . . . R R R R Requir
equir
equir
equir
equiremen
ement: t: t: t: t:
emen
emen
emen
The insert is connected to a listed stainless steel
flexible connector that extends beyond the chimney
flue tile liner. A sealed block-off plate must be
installed at the damper area of the existing fire-
place. See fig. 7.
For internal chimneys, (no sides of the chimney
exposed to the outside below the roofline,) a
positive connection to the first flue tile is accept-
able provided the tile is no larger than 8" x 12".
For external chimneys (one or more sides are
exposed to the outside below the roof line, includ-
ing garages), a positive connection to the first flue
tile is acceptable provided the tile is no larger than
8" x 8".
Apply sealant
around damper
opening
Damper
Frame
Figure 7. Positive Chimney Connection - U.S.
10
Flex
Connector
Adjustable
Sealing Plate
Locking
Bracket
A 6", 7", or 8" stainless steel liner, extending the
full height of the chimney, is required for all installa-
tions where the flue tile is greater than 8" x 12" for
internal chimneys, or 9" x 8" for external chimneys.
C C C C C anada R
anada R
anada R
equir
equir
emen
emen
ement: t: t: t: t:
anada R
anada Requir
equir
equiremen
emen
The insert must be installed with a continuous
chimney liner of 6" (152 mm) diameter extending
from the fireplace insert to the top of the chimney.
The chimney liner must conform to the Class 3
requirements of CAN/ULC-S635, Standard for Lining
Systems for Existing Masonry or Factory-Built
Chimneys and Vents, or CAN/ULC-S640, Standard for
Lining Systems for New Masonry Chimneys.
See fig. 8.
Do not use aluminum or galvanized steel pipe for
chimney connection components - these materials
are not suitable for use with solid fuel.
Attach Fireplace
Conversion
Notice Plate to
Rear Wall of
Flex Connector
Pipe extends
into the flue tile
Fireplace