U.S. Requirement:
The insert is connected to a listed stainless steel
flexible connector that extends into the first chim-
ney flue tile liner. A sealed block-off plate must be
installed at the damper area of the existing fireplace.
See fig. 7.
For internal chimneys, (no sides of the chimney
exposed to the outside below the roofline,) a posi-
tive connection to the first flue tile is acceptable
provided the tile is no larger than 8" x 12".
For external chimneys (one or more sides are ex-
posed to the outside below the roof line, including
garages), a positive connection to the first flue tile is
acceptable provided the tile is no larger than
8" x 8".
A 6", 7", or 8" stainless steel liner, extending the
full height of the chimney, is required for all instal-
lations where the flue tile is greater than 8" x 12" for
internal chimneys, or 9" x 8" for external chimneys.
Canada Requirement:
The insert must be installed with a continuous chim-
ney liner of 6" (152 mm) diameter extending from
the fireplace insert to the top of the chimney. The
chimney liner must conform to the Class 3 require-
ments of CAN/ULC-S635, Standard for Lining Systems
for Existing Masonry or Factory-Built Chimneys and
Vents, or CAN/ULC-S640, Standard for Lining Sys-
tems for New Masonry Chimneys.
See fig. 8.
Do not use aluminum or galvanized steel pipe for
Figure 7. Positive Chimney Connection - U.S.
10
1 / 2 / 12
chimney connection components - these materials
are not suitable for use with solid fuel.
Installation
1. Remove the existing damper and linkage compo-
nents from the fireplace. Alternatively, you can
wire the damper plate to lock it in the open posi-
tion. Thoroughly clean the firebox and smokeshelf
area with a wire brush.
2. If the fireplace has been modified to accommo-
date installation, use anchors or masonry nails to
attach the metal Fireplace Conversion Notice Plate
(PN 220508) to the back wall of the masonry fire-
place firebox where it will be readily seen should
the insert be removed.
3. Install the Flex Connection plate according to the
manufacturer's instructions. The sealing plate may
require trimming to accommodate your specific
fireplace damper.
Flex Con-
nector Pipe
extends at
least into
the first
flue tile
Attach Fireplace
Conversion
Notice Plate
to Rear Wall of
Fireplace