Chimney Connection Requirements
U U U U U .S .S .S .S .S. . . . . Only R
Only R
Only R
equir
equir
emen
emen
Only Requir
Only R
equiremen
equir
emen
ements:
1. The insert must be connected to a code-approved
masonry chimney with a direct (positive) flue
connector into the first chimney liner section.
2. The cross-sectional area of the chimney flue may
not be less than the cross-sectional area of the
flue collar..
3. A sealed block-off plate must be installed at the
damper area of the existing fireplace, unless the
liner is connected to the top of the chimney. See
fig. 8.
4. For internal chimneys, (no sides of the chimney
exposed to the outside below the roofline,) a
positive connection into the first flue tile is accept-
able provided the tile is no larger than 8" x 12".
5. For external chimneys, (one or more sides are
exposed to the outside below the roof line,
including garages), a positive connection to the
first flue tile is acceptable provided the tile is no
larger than 8" x 8".
6. A 6", 7", or 8" stainless steel liner, extending the
full height of the chimney, is required for those
installations where the flue tile is greater than
8" x 12" for internal chimneys, or
8" x 8" for external chimneys.
In this case, a damper block-off plate is not
required.
Apply sealant
around damper
opening
Damper
Frame
Figure 8. Positive Chimney Connection with an
example of a damper block-off plate - U.S. only.
10
ts:
ts:
ts:
ts:
Flex
Connector
Adjustable
Sealing Plate
Locking
Bracket
C C C C C anada R
anada R
anada Requir
anada R
anada R
equir
equir
equir
equiremen
emen
emen
emen
ement: t: t: t: t:
The insert must be installed with a continuous
chimney liner of 6" (152 mm) diameter extending
from the fireplace insert to the top of the chimney.
The chimney liner must conform to the Class 3
requirements of CAN/ULC-S635, Standard for Lining
Systems for Existing Masonry or Factory-Built
Chimneys and Vents, or CAN/ULC-S640, Standard for
Lining Systems for New Masonry Chimneys.
See fig. 9.
Do not use aluminum or galvanized steel pipe for
chimney connection components - these materials
are not suitable for use with solid fuel.
Notice Plate to
Rear Wall of
Flex Connector
Pipe extends
into the first flue
tile
Attach
Fireplace
Conversion
Fireplace