5. To return to the System Configuration menu, press <Esc>.
Note:
When setting the Internal Rate parameter, the 2370 may not be able to generate the exact
rate. To calculate the available rates, use this equation:
Rate = Osc (PLL_N/PLL_M) (1/Div)
Where
Ocs = 16384000 Hz, 24704000 Hz, or custom oscillator rate
32 ≤ PLL_N ≤ 254
64 ≤ PLL_M ≤ 128
2 ≤ Div ≤ 65354
and PLL_N, PLL_M, and Div are even numbers

Table 13. Interface Configuration Parameters and Values

ELIM Group
L130
EIA-423/232, EIA-530,
EIA-449/422, or V.35
EdgeAccess® Universal Chassis System
Parameter
Interface Type
Operating Mode
Internal Rate (bps)
(select for Internal Mode)
TD Timing, the clock that sends
data to the fiber interface
(select for Internal, Slave, or
External Modes)
RD Timing, the clock that shifts
data to the electrical interface
(select for External Mode)
DCD Output
KG CTS(A)
(select for EIA-530)
CTS Output
(select for EIA-423/232,
EIA-449/442, or V.35, and
KG CTS(A) set to Normal)
DSR Off When
Model 2370 Model User Manual
Possible Values
EIA/423/232, EIA-530, EIA-449/422, or
V.35
Internal, Slave, External, or
Asynchronous
Type the rate, then confirm the rate
calculated from the Rate equation above
Internal Mode: SCTE, SCT, or SCT
Inverted
Slave Mode: SCTE, SCTE Sampled,
SCT, or SCT Inverted
External Mode: SCTE or SCTE sampled
SCT or SCR
Remote RTS or CLS (DCD False if CLS
is True)
Normal, +6V/GND, +6V/-6V, GND/-6V,
GND/+6V, -6V/+6V, or -6V/GND
Local RTS, Local RTS & DCD, or
Remote DTR/RI/IC
Far Local Test or Any Test On
4-7