-------------------------LINK ERROR COUNTERS----------------------------
Timer DDDD:HH:MM:SS
Composite LOS Errors
Electrical LOS Errors
SQL Rx Errors
BERT Sync Status
BERT Sync Count
BERT Bit Errors
BERT BER (1E-9)
BERT Up Time
Hit 'TAB' to reset timers and counters, 'ESC' to return to previous menu.

Figure 19. Link Error Counters Screen

Table 18. Link Error Counters Definitions

Item
Timer
Composite LOS Errors
Electrical LOS Errors
SQL Rx Errors
BERT Sync Status
BERT Sync Count
BERT Bit Errors
BERT BER (1E-9)
BERT Up Time
The Bit Error Rate Test (BERT) sends a continuous sequence to check for bit errors while the optical
signal remains in sync.
EdgeAccess® Universal Chassis System
Local
Pri.
Sec.
0:00:06:47
0
0
0
OK
0
0
0
0:00:06:47
Number of days, hours, minutes, and seconds since the last reset
Number of optical loss of signal errors
Number of electrical loss of signal errors
Number of received squelch occurrences
Reports loss if the BERT out of sync error rate exceeds 10
OK if signal is good
Number of good to faulty patterns
Number of bits with errors in the received pattern
Number of bit errors during this BERT up time
How long BERT is available and running
Model 2370 Model User Manual
Remote
Pri.
0:00:06:42
0:00:06:42
Definition
Sec.
0
0
0
OK
0
0
0
E-9
or