Figure 12. Functional Configuration Screen; Table 12. Functional Configuration Option Definitions - Canoga Perkins 2370 User Manual

High-speed universal fiber optic modem universal chassis system
Table of Contents

Advertisement

-------------------------FUNCTIONAL CONFIGURATION-------------------------
Local Pri.
Oscillator(MHz) 6.144
Interface Type
EIA-423/232
Operating Mode
Internal
Int. Rate (bps) 384000
TD Timing
SCTE
RD Timing
SCR
DCD Output
Far RTS
CTS Output
Local RTS
DSR Output
Far Local Test Far Local Test
KGCTS(A)/RLSD
Normal
Delay (ns)
N/A
T1 Output
N/A
LOS Detection
On
Redundancy
Auto/Active
Select [1] to configure local interface, [2] to configure remote interface,
[3] LOS Detection, [4] redundancy setup:

Figure 12. Functional Configuration Screen

Table 12. Functional Configuration Option Definitions

Menu Item
1) Configure local interface
2) Configure remote interface Enter values for the remote interface parameters
3) LOS Detection
4) Redundancy setup
You can set values for various parameters for both local and remote modems. To configure an
interface, see Tables 12 and 13 and follow these steps: To configure the 2370 functions, follow these
steps:
1. From the Main Menu type 2, "Functional Configuration," and press <Enter>.
2. From the Functional Configuration menu type 1, "to configure local interface," or 2, "to
configure remote interface," and press <Enter>.
3. At each successive prompt, press <Space> to cycle through the options and press <Enter> to
select an option or type a number to select values for the parameters, according to the information
in Table 13.
4. To set up LOS Detection or Redundancy, type
Note:
LOS detection differs by application. For a 530 or 422 (with controls) interface, LOS uses
RTS. For a T22, D22, and T88 interface, LOS uses SCTE. For T1/E1, LOS tracks 175
consecutive zeros. TTL/BNC interfaces do not support LOS.
4-6
Local Sec.
6.144
EIA-423/232
Internal
384000
SCTE
SCR
Far RTS
Local RTS
Normal
N/A
N/A
On
Auto/Inactive
Enter values for the local interface parameters
Set to On or Off
Set to Auto, Manual Primary (Man Pri) or Secondary (Man Sec),
or Off; shows current activity
or
3
Model 2370 Model User Manual
Remote Pri.
6.144
EIA-530
Slave
384000
N/A
SCT
CLS
Remote DTR
Any Test On
+6V/GND
N/A
N/A
On
Auto/Active
Description
and follow the prompts on the screen.
4
Remote Sec.
6.144
EIA-530
Slave
384000
N/A
SCT
CLS
Remote DTR
Any Test On
+6V/GND
N/A
N/A
On
Auto/Inactive