Figure 3. P53 Interface For Internal Clock; Figure 4. P53 Interface For External Function - Canoga Perkins 2370 User Manual

High-speed universal fiber optic modem universal chassis system
Table of Contents

Advertisement

Use the Internal configuration when the network equipment is set for Internal Timing (see Figure 3).
In this application, the modems act as the network timing source. When connecting KG or KIV
encryptors on the Black side, go to the Functional Configuration screen and set the interface
configuration parameters: set the operating mode to Internal, then set the Internal Rate, then set the
delay time; for details, see Section 4.7.
J1, DB-25
RXD
SCR
SCT
SCTE
TXD

Figure 3. P53 Interface for Internal Clock

Use the External configuration when the network equipment is set for Network or Internal Timing
(see Figure 4). In this application, the modems act as an extension of the Red side cable in a true tail
circuit. When connecting KG or KIV encryptors on the Red side to a DTE device, go to the
Functional Configuration screen and set the interface configuration parameters: set the operating
mode for the modem at the Red end to External and the modem at the DTE end to Slave; for details,
see Section 4.7.
J1, DB-25
RXD
SCR
SCT
SCTE
TXD

Figure 4. P53 Interface for External Function

3-4
FIFO
RX Data
RX Clock
Delay Line
Internal
Clock
TX Clock
TX Data
FIFO
RX Data
RX Clock
Delay Line
Internal
Clock
TX Clock
TX Data