PROBLEM
Engine will not
start (see
Engine Manual
for further
engine trouble-
shooting)
No or low
pressure
(initial use)

TROUBLESHOOTING GUIDE

CAUSE
1.
No fuel.
2.
Pressure builds up after
two pulls on the recoil
starter or after initial use.
3.
Not choked.
4.
Spark plug wire not
attached.
5.
Choke lever in the
"Choke" position on a
"hot" engine or an engine
that has been exposed to
thermal heat for a long
period of time.
6.
Fuel valve closed
1.
Wand not in high pres-
sure.
2.
Low water supply.
3.
Leak at high pressure
hose.
4.
Nozzle obstructed.
5.
Water filter screen
clogged.
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
17- ENG
CORRECTION
Add Fuel.
Squeeze gun trigger to
relieve pressure.
Choke engine, place
engine in the choke posi-
tion.
Attach spark plug wire.
Move choke to the "No
Choke" position.
Move the fuel valve knob
to the "Open" position.
See How to Use Wand
paragraph in the
Operation Section.
Water supply must be at
least 5 GPM @ 20 PSI.
Repair leak. Apply sealant
tape if necessary.
Clean nozzle with paper
clip or nozzle cleaning
tool, pour water into noz-
zle end to flush out ob-
struction.
Remove and clean filter.
D25130