4. Ever-on Mode
Storing the Pump
Before storing the pump, it is recommended to empty the pump body of any water.
Turn the drain screw (5) anti-clockwise and remove from the pump body. This will
drain any excess water. Replace the drain screw (5) (Fig. 12).
Note: Ensure the gate valve on your water tank is not left open as this will allow
water to drain from the tank.
In ordinary conditions, this pump does not require any maintenance.
Make sure the pump is disconnected from electric power supply before performing maintenance operation.
Cleaning the pump body
Use a moist cloth to wipe down the pump body (5). Allow to dry thoroughly before storing in a dry location that is
protected from bad weather conditions.
If the pump is not going to be used for a long period of time, it is advisable to rinse with water. Ensure the pump
is completely dry before storing.