Operations; Starting And Stopping The Saw - Steel City 35903 User Manual

10” riving knife cabinet saw
Table of Contents

Advertisement

1. First remove the access panel on the left side of
the saw cabinet. SEE FIG. 37
Fig. 37
A
2) While holding the 8mm hex head bolt(A) with a
wrench, loosen the hex nut only slightly (less than
th
1/8 of a turn.
SEE FIG. 38
CAUTION
!
A separate electrical circuit should be used for your
table saw. The circuit should not be less than 14
AWG wire and should be protected with a 15-amp
time lag fuse.
Have a qualified electrician repair or replace
damaged or worn cord immediately.
Before connecting the motor to the power line, make
certain the switch is in the
that the electric current is of the same rating as the
motor nameplate. All line connections should make
good contact.
Running on low voltage or long, underrated extension
cords will damage the motor.
WARNING
!
DO NOT
expose the table saw to rain or operate the
in damp locations.
MAKE SURE
all parts have been assembled
correctly and are in working order.
KEEP
table surface clear of tools and debris before
starting table saw.

STARTING AND STOPPING THE SAW

OPERATIONS

"OFF"
position and be sure
Fig. 38
3)Tighten the 5mm hex head bolts(B ) slightly.
Correct adjustment is when a good snug sliding fit is
obtained without any side play or movement between
the mating dovetail surfaces. The adjustment should
not be too tight that it restricts the sliding movement
when the blade is raised and lowered or too loose
that it affects accuracy.
4)Once proper fit is achieved, retighten the (2)8mm
hex head bolts(A) and M5 hex nut against the
casting.
Fig. 39
1. The ON/OFF switch is located under the front rail on
the table saw.
2. To turn the table saw on, press the green ON
(A) in one-half inch.
on the switch to insure that the switch must be
completely pressed before the saw will START.
FIG 39.
3. To turn the table saw off, press the large red
paddle (B) or lift the paddle and press directly on the
red "OFF" button.
4. When the table saw is not in use, the
should be locked so that it cannot be started.
29
B
There is a safety feature
Note:
"ON"
button
button
SEE
"OFF"