AIMB-250 Series
2.4.9
Serial Port 1 Connector in RS-422 Mode (CN1)
2.4.9.1 Signal Description – Serial Port 1 Connector in RS-422 Mode (CN1)
Signal
TxD+/-
RxD+/-
40 AIMB-250 Series User's Manual
Serial output. This differential signal pair sends serial data to the communication
link. Data is transferred from Serial Port 2 Transmit Buffer Register to the
communication link, if the RTS register of the Serial Port 2 is set to LOW.
Serial input. This differential signal pair receives serial data from the
communication link. Received data is available in Serial Port 2 Receiver Buffer
Register.
Signal
PIN PIN
TxD-
1
TxD+
3
GND
5
NC
7
NC
9
Signal Description
Signal
2
RxD+
4
RxD-
6
NC
8
NC
10
NC