SUMMARY OF AUDIBLE NOTIFICATIONS
S O U N D
C A U S E
LOUD "BEEPING" (keypads)
FIRE ALARM
Temporal pulsed sound from
external sounder* & keypad(s)
LOUD, CONTINUOUS
BURGLARY/AUDIBLE
Keypad & External
EMERGENCY ALARM
ONE SHORT BEEP
a. SYSTEM DISARM
(not repeated)
b. SYSTEM ARMING ATTEMPT
Keypad only
WITH AN OPEN ZONE.
c. BYPASS VERIFY
ONE SHORT BEEP
SYSTEM IS IN TEST MODE
(once every 15 seconds)
Keypad only
ONE BEEP every 40 sec.
LOW BATTERY AT A TRANSMITTER
Keypad only
TWO SHORT BEEPS
ARM AWAY OR MAXIMUM
Keypad only
THREE SHORT BEEPS
a. ARM STAY OR INSTANT
Keypad only
b. ZONE OPENED WHILE SYSTEM
IS IN CHIME MODE.
RAPID BEEPING
a. TROUBLE
Keypad only
b. MEMORY OF ALARM
SLOW BEEPING
a. EXIT DELAY WARNING (if
Keypad only
programmed)
b. ENTRY DELAY WARNING
* If bell is used as external sounder, fire alarm is temporal pulsed ring; burglary/audible emergency is steady ring.
* *
Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer.
*** Loss of system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power only).
(FIXED-WORD DISPLAY KEYPADS)
DISPLAY
FIRE & ALARM!is displayed; zone number of zone in alarm is displayed.
ALARM is displayed; zone number of zone in alarm is also displayed.
a. READY is displayed.
b. The number of the open protection zone is displayed.
c. Zone numbers of the bypassed protection zones are displayed (one beep is
heard for each zone displayed). Subsequently, the following is displayed:
BYPASS and READY
Opened zone numbers will appear.
BAT displayed with zone number of transmitter.
AWAY or AWAY & INSTANT!is displayed. Red ARMED indicator is lit.
a. STAY or INSTANT is displayed. Red ARMED indicator is lit.
b. CHIME displayed; zone number of open protection zone will be displayed if the
[ ] key is pressed.
a. CHECK!displayed. Zone number of troubled protection zone is displayed.
b. FIRE or ALARM is displayed; zone number of zone in alarm is displayed.
a. AWAY or AWAY & INSTANT is displayed.
b. Exceeding the entry delay time without disarming causes alarm.