A-3 RPM OFFSET

RPM OFFSET

This feature can adjust boost control rate at 8-rpm points to prevent
boost falling off and achieve consistant boost pressure throughout
the rpm curve.
-Example-
Boost starts to fall off after 5000 rpm.
(1) Confirm where the boost falls off and input the rpm in the rpm
point 1.
(2) Input the adjustment rate in the rest of the rpm points.
BOOST
SET Point
5000 5500
There is a limit to how much adjustment can be made due to
turbocharger size, wastegate's capacity and extreme exhaust
pressure.
21
This is where the adjustment
starts.
(1) HI / LO BOOST, OVER TAKE
This feature can be turned
on/off for each boost setting.
Select ON / OFF
(2) RPM
Input the 8 rpm points where
adjustment is required.
Input 0~9900rpm at 100
increments.
(3) DUTY
Input the adjustment rate to
the 8 rpm points.
Input –100~100% value.
AFTER
BEFORE
rpm
Important!