NOTE: ceramic tile, or any tile, requires a continuous sheet beneath to prevent the possibility of embers
falling through to the combustible floor if cracks or separation should occur in the finished surface, this
would include floor protection for Built-in raised hearths. Check local codes for approved alternatives.
Clearances are measured from the sides, back and face (door opening) or stove body
(refer to fig Nº 4 ).
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES
INSTALL VENT WITH CLEARANCES SPECIFIED BY
COMBUSTION AIR SUPPLY
For a mobile home installation the stove must be connected. To an outside source of combustion air.
A 2" inside diameter metallic pipe, either flexible or rigid, may be attached to the inlet at the stove's
rear (refer to figure 5). A rodent guard (minimum 1/4" wire mesh) /wind hood must be used at the
terminus. All connections must be secured and airtight by either using the appropriately sized hose
clamp and/or UL-181-AP foil tape.