OWNER´S MANUAL
ELECTRICAL INSTALLATIONS
This stove is provided with a 6-foot grounded electrical cord extending from the rear of the stove.
We recommend connecting to a good quality surge protector that is plugged into a standard three-
prong, 120V, 60hz electrical outlet. Voltage variations can lead to serious performance problems.
The Bosca SPIRIT 500 Pellet Stove electrical system is designed for 120V AC with no more than
5% variation. BOSCA cannot accept responsibility for poor performance or damage due to inadequate
voltage. If connected to an older, two-prong outlet, a separate ground wire should be run to a
proper ground (refer this to a qualified technician). Always route the electrical cord so that is will
not come in contact with any hot part of the stove.
SPECIAL MOBILE HOME
REQUIREMENTS
WARNING: DO NOT INSTALL IN A SLEEPING ROOM.
For installation in a mobile home, an outside source of combustion air must be used (see
"COMBUSTION AIR SUPPLY").
The stove must be grounded to the steel chassis of the home with 8 Ga. Copper wire
using a serrated or star washer to penetrate paint or protective coating to ensure
grounding.
The Stove must be securely fastened to the floor of the mobile home using 2, 1/4"
lag bolts that are long enough to go through both a hearth pad, if used, and the floor
of the home.
Refer to "VENTING" for proper exhaust configurations.
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR,
WALL AND CEILING/ROOF MUST BE MAINTAINED.