OWNER´S MANUAL
Possibles Causes
9.-Control board not sending power to air
switch.
10.-Air switch has failed (very rare)
STOVE SHUTS OFF AND THE #3 LIGHT FLASHES
Possibles Causes
1.The hopper is out of pellets.
2.-Hopper lid left open.
3.-The air damper is too far open for a low
feed setting.
4.-The burnpot is not pushed completely to
the rear of the firebox.
5.-The burnpot holes are blocked
6.-The air inlet, the interior chambers, or
exhaust system has a partial blockage.
Possibles remedies (Unplug stove first
when possible)
There should be a 5-volt current (approximately)
going to the air switch after the stove has been
on for 30 seconds.
To test the air switch, you will need to disconnect
the air hose from the body of the stove. With
the other end still attached to the air switch, very
gently suck on the loose end of the hose (you
may want to remove the hose entirely off the
stove and the air switch first and make sure it is
clear). If you hear a click, the air switch is working.
BE CAREFUL, TOO MUCH VACUUM CAN
DAMAGE THE AIR SWITCH.
Possibles remedies (Unplug stove first
when possible)
Refill the hopper.
Lid must be closed for pellets to feed.
Make sure that the air intake collar on the burnpot
is touching the rear wall of the firebox.
Make sure that the air intake collar on the burnpot
is touching the rear wall of the firebox.
Remove the burnpot and thoroughly clean it.
Follow all cleaning procedures in the
maintenance section of the owner's manual.
-32-