OWNER´S MANUAL
VERTICALLY WITH NEW CHIMNEY SYSTEM
( Refer to Figures 7a-7b)
PIPE
ADAPTER
NOTE: Follow L-Vent chimney manufacturer's instructions.
OPTION: Install L-Vent elbow in place of clean-out tee. Locate stove. Drop plumb bob to center
of tee outlet, mark point on ceiling. Install ceiling support and L-Vent pipe per L-Vent manufacturer's
instructions.
Always maintain 3" clearance from combustible materials. When passing through
additional floors or ceilings, always install firestop spacer.
After lining up for hole in roof, cut either around or square hole in roof, always 3" larger
all the way around pipe. Install upper edge and sides of flashing under roofing materials,
nail to the roof along upper edge. Do not nail lower edge. Seal nail head with non-
hardening waterproof mastic.
Apply non-hardening, waterproof mastic where the storm collar will meet the vent and
flashing. Slide storm collar down until it sits on the flashing. Seal and install cap.
Mobile home installations must use a spark arrester.
24" MIN
ATTIC
INSULATION
SHIELD
CEILING
SUPPORT/
FIRESTOP
SPACER
TEEWICH
CLEAN-OUT
ADAPTER
fig. Nº7a
24" MIN
4 FT.
fig. Nº7b