2-11. DOOR SENSOR
REPLACEMENT
Step 4
Step 5
Step 6
306
1. Remove electrical power supplied to unit.
To avoid electrical shock or property damage, move
the power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove appropriate side panel.
3. For replacing the sensor on the control side, the
control panel and control box must be removed per Control
Board Replacement Section.
4. Using a 3/8" socket, remove the nuts securing the
sensor bracket, and remove bracket from unit.
5. Using a Phillips head screwdriver and a 5/16" wrench,
remove screws from switch and remove switch from
bracket.
6. Cut wires behind splices and then splice wires of new sensor
on existing wires.
7. Install new sensor on bracket, and install bracket assembly
onto unit.
8. Replace side panels and restore power to unit.
Do not over-tighten the screws securing the sensor to the
bracket, or damage to the sensor will result.