2-17. CONTROL BOARD
REPLACEMENT
Step 3
Step 4

2-18. RELAYS

1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move
the power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the Phillips head screws securing the side
panel closest to the controls and then remove side panel.
3. Pull connectors from board.
4. Using a 5/16" socket, remove the nuts securing the
control board and remove control board.
5. Install new board in reverse order , and restore power
to unit.
The solid state relays receive messages from the control board
and operate the components in the rotisserie. See wiring
diagrams to help locate the desired relay .
Checkout:
1. Remove electrical power supplied to unit.
To avoid electrical shock or property damage, move
the power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Using a Phillips head screwdriver , remove the side panel
closest to the controls.