2-9. CAPACITOR REPLACE-
MENT - BLOWER MOTOR
Step 4
2-10. CAPACITOR REPLACE-
MENT - DRIVE MOTOR
Step 3
Step 4
2-8
1. Remove electrical power supplied to unit.
To avoid electrical shock or property damage,
move the power switch to OFF and disconnect
main circuit breaker, or unplug cord at wall
receptacle.
2.
Remove the side panel closest to the controls.
3.
Disconnect wires from wire nuts.
4.
Using a 1/2" socket, remove nut securing capacitor to
bracket and remove capacitor .
5.
Install new capacitor in reverse order .
1. Remove electrical power supplied to unit.
To avoid electrical shock or property damage, move
the power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove side panel closest to controls.
3. Disconnect wires from capacitor .
4. Remove the three Phillips head screws from the
capacitor , and remove capacitor from unit.
5. Install new capacitor in reverse order .