Control Board Speaker Replacement; Meat Probe Receptacle Replacement - Henny Penny SCR-6 Technical Manual

Hide thumbs Also See for SCR-6:
Table of Contents

Advertisement

2-15. CONTROL BOARD
SPEAKER
REPLACEMENT
Step 4
2-16. MEAT PROBE
RECEPTACLE
REPLACEMENT
Step 3
2-12
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move
the power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the side panel closest to the controls.
3. Unplug the red connector from the board.
4. Using a Phillips head screwdriver , remove the two screws
securing the speaker and remove the speaker .
5. Replace with new speaker in reverse order .
1. Remove electrical power to unit.
To avoid electrical shock or property damage, move
the power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the side panel closest to the controls.
3. Using a 3/8" socket remove the keps nuts from
receptacle bracket and remove bracket from unit.
4. Unplug the 2-pin connector from the P-5 receptacle on
the control board.
5. Using a small Phillips head screwdriver , remove the s c r e w
securing the probe receptacle to the bracket.
6. Replace with new receptacle in reverse order of
previous steps.