2-12. HIGH LIMIT
(Continued)

2-13. BLOWER

2-10
6. Remove the high limit.
7. Install a new high limit in reverse order.
8. Reconnect the two wires to the high limit.
9. Replace the access panel to the module.
10. Reconnect the electrical supply to the cabinet.
Procedures for blower motor replacement are the same on
both blowers.
1. Disconnect the electrical supply to the cabinet.
Step 3
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the access panel from the top of the cabinet.
3. Remove the three (3) screws that fasten the blower motor to
the blower housing.
4. Cut the two (2) blower wires approximately 2" away from the
Step 4
blower.
5. Lift the blower motor and wheel out of the blower housing.
6. If replacing motor, fan, and wheel as an assembly, install new
assembly in reverse order. If replacing just the motor, con-
tinue onto step 7.
Models HHC-90X/HC-15
203