Board Description and Memory Maps
When programming the tick timer for periodic interrupts, the counter should be cleared to zero
by software and then enabled. If the counter does not initially start at 0, the time to the first
interrupt may be longer or shorter than expected. The rollover time for the counter is 71.6
minutes.

Table 1-21 Tick Timer Compare Registers

Tick Timer 1 Compare Register - 0xE202 0014 (32 bits)
Tick Timer 2 Compare Register - 0xE202 0024 (32 bits)
Tick Timer 3 Compare Register - 0xE202 0034 (32 bits)
Tick Timer 4 Compare Register - 0xE202 0044 (32 bits)
BIT
FIELD
OPER
RESET

1.3.16.4 Counter Registers

When enabled, the tick timer Counter register increments every microsecond. Software may
read or write the counter at any time.

Table 1-22 Tick Timer Counter Registers

REG
BIT
FIELD
OPER
RESET
1.3.17

Geographical Address Register

The VMEbus Status register in the TSi148 provides the VMEbus geographical address of the
MVME3100. This register reflects the inverted states of the geographical address pins at the 5-
row, 160-pin P1 connector.
32
31
Tick Timer Compare Value
R/W
0
Tick Timer 1 Counter Register - 0xE202 0018 (32 bits)
Tick Timer 2 Counter Register - 0xE202 0028 (32 bits)
Tick Timer 3 Counter Register - 0xE202 0038 (32 bits)
Tick Timer 4 Counter Register - 0xE202 0048 (32 bits
31
Tick Timer Counter Value
R/W
0
MVME3100 Single Board Computer Programmer's Reference (6806800G37A)
Geographical Address Register
0