SECTION 9—SHROUDS/FRAME

Removing/Installing the Pivot Tube

NOTE: For this procedure, refer to FIGURE 9.2.
NOTE: Reverse this procedure to reassemble the side frame.
1. Remove the side shroud and shroud plate. Refer to Removing/Installing the Shrouds
on page 71.
2. Remove the front head tube assembly. Refer to Removing/Installing the Front
Headtube Assembly on page 48.
3. Remove the locknut and spacer securing the pivot tube to the mounting pin.
NOTE: Two nylon bushings are located in each end of the pivot tube.
4. Remove the pivot tube from the lower mounting pin.
Locknuts
Removing/Installing the Walking Beam and/or SureStep
Springs
Replacement of the walking beam and or the SureStep spring MUST be performed
by Invacare service personnel ONLY - otherwise injury or damage may result.
®
Pronto
M91 and M94
Side Frame
Spacer
Pivot Tube
FIGURE 9.2 Removing/Installing the Pivot Tube
WARNING
Nylon Bushings
74
Mounting Pin
Part No. 1125038