Adjusting/Replacing Telescoping Front Rigging Supports - Asba - Invacare Pronto M91 Service Manual

With surestep
Hide thumbs Also See for Pronto M91:
Table of Contents

Advertisement

SECTION 6—FRONT RIGGINGS
Adjusting/Replacing Telescoping Front Rigging
Supports - ASBA
NOTE: For this procedure, refer to FIGURE 6.7.
1. Remove the two (2) mounting screws, spacers and locknuts that secure the telescoping
front rigging support to the seat frame.
2. Perform one (1) of the following:
• Slide existing telescoping front rigging support to one (1) of three (3) depth
positions.
• Remove existing telescoping front rigging.
3. Secure telescoping front rigging at desired depth with existing two (2) mounting
screws, spacers, and locknuts. Securely tighten.
NOTE: The two (2) telescoping front rigging supports can be positioned at different depths
depending on the need of the user.
Spacer
Locknut
FIGURE 6.7 Adjusting/Replacing Telescoping Front Rigging Supports - ASBA
®
Pronto
M91 and M94
Mounting
Screws
Spacer
Locknut
60
Telescoping Front
Rigging Support
Part No. 1125038