Float Valve Removal
1. Place the toggle switch in the OFF position, turn
off the water supply and disconnect electrical
power to the ice machine.
2. Disconnect water supply line at float valve quick
disconnect by depressing stainless steel lever.
3. Remove water float valve coil.
A. Depress coil and rotate 1/4 turn
counterclockwise.
B. With coil wires attached, lift coil off enclosure
tube.
4. QF0800/QC0700 ONLY Rotate quarter turn
fasteners counterclockwise.
5. QF0800/QC0700 ONLY Remove cotter key and
pin from ice chute.
6. Remove top cover from float reservoir.
7. Lift float valve out of float reservoir.