Qc0700/Qf0800/Qf2200/Qf2300 - Manitowoc QF0400 Technician's Handbook

Hide thumbs Also See for QF0400:
Table of Contents

Advertisement

QC0700/QF0800/QF2200/QF2300

Preventative Maintenance Cleaning Procedure
Step 1 Remove front and top covers and set the
toggle switch to the OFF position.
Step 2 To start a cleaning cycle, move the toggle
switch to the CLEAN position. Water will flow through
the water dump valve and down the drain. The flush,
gear motor, speed, dump valve and water solenoid
lights will energize to indicate the ice machine is in the
cleaning mode.
Step 3 Remove the 1-1/2 in. plug from the top cover
of the water reservoir. Wait about one minute or until
the Dump Valve light de-energizes, then add the
proper amount of Manitowoc Ice Machine Cleaner and
reinstall the plug.
Use Manitowoc clear (P/N 000000084) Ice
Machine Cleaner only. It is a violation of Federal
law to use these solutions in a manner
inconsistent with their labeling. Read and
understand all labels printed on bottles before
use.
QF0800/QC0700
QF2200/QF2300
Step 4 The ice machine will automatically time out
four Flush and Rinse cycles, and then stop. The Flush
light remains energized until the toggle switch is
moved to the OFF position. This entire cycle lasts
approximately 11 minutes.
48
! Caution
Model
Amount of Cleaner
(Part # 000000084)
3 oz. (90 ml)
3 oz. (90 ml)
Part Number 80-1230-9 10/10

Hide quick links: