Manitowoc QF0400 Technician's Handbook page 51

Hide thumbs Also See for QF0400:
Table of Contents

Advertisement

ADD SOLUTION HERE
Step 3 The ice machine will automatically time out a
series of flush and rinse cycles, and then stops. This
entire cycle lasts approximately 30 minutes.
NOTE: Periodic cleaning must be performed on
adjacent surface areas not contacted by the water
distribution system.
NOTE: The ice machine may be set to start and finish
a cleaning procedure, and then automatically start ice
making again.
A. After cleaner is added move the switch from
CLEAN to ICE position.
B. When the cleaning cycle is complete ice
making will start automatically.
Part Number 80-1230-9 10/10