Procedure to Clean Heavily Scaled Ice Machines
Step 1 Remove all ice from the bin.
Step 2 Remove front and top covers and set the
toggle switch to the OFF position.
Step 3 Disconnect water supply line at float valve
quick disconnect by depressing stainless steel lever.
Step 4 Refer to chart below:
Premix cleaner with lukewarm water in a
non-metallic container.
Model
QF0800/
QC0700
QF2200/
QF2300
Step 5 Remove all water from the evaporator and
water reservoir. Start an ice making cycle by moving
the toggle switch to the ICE position. Water will flow
through the water dump valve and down the drain for
45 seconds. After 45 seconds move the toggle switch
to the OFF position. Remove the plug from the top
cover of the water reservoir. Add the entire cleaner/
water solution and re-install the plug. Leave the
cleaner/water solution in the evaporator for a
minimum of 4 hours.
Step 6 Move the toggle switch from OFF to ICE. The
cleaner/water solution will flow through the water
dump valve and down the drain for 45 seconds.
Move the toggle switch to the OFF position, then
follow the standard cleaning and
sanitizing procedures for the model ice machine you
are cleaning.
54
Water
Reservoir
Capacity
48 oz (1.4 L)
72 oz (2.1 L)
Amount of Cleaner
Part Number 000000084
Cleaner
32 oz (0.94 L)
48 oz (1.4 L)
Part Number 80-1230-9 10/10
Water
16 oz (0.5 L)
24 oz (0.7 L)