PROPANE CYLINDER TANK
•
The heater comes equipped with a hose assembly for hook-up to a standard propane gas tank. The propane
tank is NOT included.
•
A dented, rusted or damaged propane tank may be hazardous and should be checked by your tank supplier.
Never use a propane tank with a damaged valve connection.
•
The propane tank must be constructed and marked in accordance with the specifications for LP gas cylin-
ders per the US Department of Transportation (DOT).
•
The propane tank must be designed to provide for vapor withdrawal from the operating cylinder.
•
Never connect an unregulated propane tank to the heater.
LEAK TESTING
•
Gas connections on the heater are gas tested at the factory prior to shipment. A complete gas tightness
check must be performed at the installation site due to potential shipment irregularities or excessive pres-
sure being applied to the heater as well as to check final installation of components by the consumer.
TO LEAK TEST
•
Make a soapy solution of one part liquid detergent and one part water. The soap solution can be applied
with a spray bottle, brush, or rag. Soap bubbles will appear where a leak is present.
•
Make certain the safety control valve is in the OFF position (at the control panel of the head unit).
•
Turn the gas supply ON at the propane cylinder valve. Apply/spray several drops on the regulator hose to
gas inlet hose connection, and the regulator to tank cylinder connection. (Small bubbles indicate a leak)
•
If a leak is present, turn OFF the gas supply, loosen and then re-tighten and leaking fittings, turn gas supply
ON again and recheck. Repeat as needed.
LOCATING HEATER FOR USE
BE CAREFUL : When certain material or items are left under the heater
while in use, they will be subjected to radiant heat and could be
seriously damaged!
•
The heater is primarely for heating of outdoor patios, decks, spas,
pools and outdoor home working areas.
•
This unit is designed for RESIDENTIAL use only!
•
Always ensure that adequate fresh air ventilation is provided. Follow
the MINIMUM spacing tolerances as indicated AT ALL TIMES!
•
The installation must conform with local codes, or in the absence
of local codes, with National Fuel Gas code, ANSI/NFPA 58 or ANSI
Z233.1-1998. (Canada – CAN/CGA-B149.1 & 2-M86)
•
The heater must be placed on stable, level, firm ground.
•
Never operate in an explosive atmosphere. Keep away from areas
where gasoline or other flammable liquids or vapors are stored or
used.
INSTRUCTIONS - 10