Do you have a question about the QUAD SCAN PRO and is the answer not in the manual?
Questions and answers
MERVYN SMITH
March 16, 2025
one scanner will not reset. fitted 2x brand new stepping motors, yet still the same. ok up and down but just twitchy for side to side. swapped motors over, still the same. does not go into reset mode
1 comments:
Mr. Anderson
May 14, 2025
The cause could be that Pan or Tilt inversion is incorrectly set. If inversion settings are activated when they shouldn't be, it may cause irregular or twitchy movement. To check and correct this:
1. For Pan inversion: Press MENU until “PAN” is displayed, press ENTER, then select NO and press ENTER to deactivate if needed. 2. For Tilt inversion: Press MENU until “TILT” is displayed, press ENTER, then select NO and press ENTER to deactivate if needed.
Also, ensure the reset function is properly used: Press MENU until “RSET” is displayed, press ENTER, then select YES and press ENTER to reset the unit.
Need help?
Do you have a question about the QUAD SCAN PRO and is the answer not in the manual?
Questions and answers
one scanner will not reset. fitted 2x brand new stepping motors, yet still the same. ok up and down but just twitchy for side to side. swapped motors over, still the same. does not go into reset mode
The cause could be that Pan or Tilt inversion is incorrectly set. If inversion settings are activated when they shouldn't be, it may cause irregular or twitchy movement. To check and correct this:
1. For Pan inversion: Press MENU until “PAN” is displayed, press ENTER, then select NO and press ENTER to deactivate if needed.
2. For Tilt inversion: Press MENU until “TILT” is displayed, press ENTER, then select NO and press ENTER to deactivate if needed.
Also, ensure the reset function is properly used: Press MENU until “RSET” is displayed, press ENTER, then select YES and press ENTER to reset the unit.
This answer is automatically generated