Installation Manual
H3C S5100-SI/EI Series Ethernet Switches

3.7.3 XENPAK Optical Module

I. Appearance and front panel
Figure 3-35 Appearance of an XENPAK optical module
Figure 3-36 Front panel of an XENPAK optical module
II. Installation
Step 1: Put on an ESD-preventive wrist strap and verify the ESD-preventive wrist strap
properly grounded. Then take out the XENPAK optical module from the package.
Step 2: Loosen the two mounting screws on the small cover plate in the middle on the
filler panel with a screwdriver and remove the small cover plate.
Note:
When installing an XENPAK optical module, you do not need to remove the whole filler
panel. Just remove the small cover plate in the middle on the filler panel.
Step 3: Hold the fastening screws on the front panel of the XENPAK optical module,
and gently push the XENPAK optical module in along the slot guide rail until the
XENPAK optical module is in close contact with the switch.
3-26