Replacement routines
4.6
Replacing fans
4.6.1
Replacing the front fan module (system fan 1)
Part number: C26361-K1007-B891
Ê Shut down the server and disconnect the AC power cord from the system.
Ê Remove the side cover as described in section
Ê Bring the server to its horizontal position.
Ê Open the HDD cage as described in section
Ê Remove the air duct as described in section
Figure 56: Disconnecting the front fan cable
Ê Disconnect the FAN1 SYS connector of the defective fan module from the
system board.
72
Service Supplement
4.1.1.1 on page
4.1.2.1 on page
25.
4.1.4.1 on page
33.
23.
TX100 S2