FIG. 10 AXlink 12 VDC power supply wiring example
If you are using power from AXlink, disconnect the wiring from the Axcess Control
System before wiring the AXB-TM5.
Use a 12 VDC power supply when the distance between the control system and AXB-TM5 exceeds
the limits described in the Wiring Guidelines section on page 4. Make sure to connect only the
GND wire on the AXlink connector when using a 12 VDC power supply. Do not connect the PWR
wire to the AXlink connector's PWR (+) terminal.

IRX-SM connections

Connect one or more (eight maximum in parallel) optional IRX-SM sensors to the AXB-TM5 as
shown in FIG. 11. You can also use TX-series wired control panels.
To IRX-SG
FIG. 11 IRX-SM connections
This configuration is for 40 kHz operation only.
AXB-TM5 Television Manager
GND
IN
AUX
PWR
Connection and Wiring
12 VDC power
supply
PWR
AXP
AXM
GND
GND
OUT
IRX-SM #2
AUX OUT
+12 VDC
GND
OUT
IRX-SM #1
AUX OUT
+12 VDC
7