Code Options - IBM MiEM78P468L Product Specification

Ibm 8-bit microcontroller product specification
Table of Contents

Advertisement

6.11 Code Options

The EM78P468N/L has one Code Option word that is not a part of the normal program
memory. The option bits cannot be accessed during normal program execution.
Code Option Register and Customer ID Register arrangement distribution:
Word 1 of code options is for customer ID code application.
Bit 12~Bit 0
Word 0 of Code Options is for IC function setting. The following are the settings for
OTP IC programming :
Bits12~10
1
Bits 12 ~ 10: Not used.
These bits are set to "1" all the time.
Bit 9 (CYES): Cycle select for JMP and CALL instructions
CYES = "0": only one instruction cycle (JMP or CALL) can be executed
CYES = "1": two instructions cycles (JMP and CALL) can be executed
Bit 8 (HLFS): main or sub-oscillator select
HLFS = "0": CPU is set to select sub-oscillator when reset occurs.
HLFS = "1": CPU is set to select main-oscillator when reset occurs.
Bit 7 (ENWDTB): Watchdog timer enable/disable bit.
ENWDTB = "0": Enable watchdog timer.
ENWDTB = "1": Disable watchdog timer.
Bit 6 (FSMD): sub-oscillator type selection.
Bits 5, 4 (FMMD1, 0): Main Oscillator Type Selection
FSMD
0
0
0
1
1
1
Product Specification (V1.5) 02.15.2007
(This specification is subject to change without further notice)
Word 1
Bit 9
Bit 8
Bit 7
CYES HLFS ENWDTB FSMD FMMD1 FMMD0 HLP
FMMD1
FMMD0
0
0
0
1
×
1
0
0
0
1
×
1
EM78P468N/EM78P468L
Word 0
Bit 6
Bit 5
Bit 4
Main Oscillator Type
RC type
Crystal type
PLL type
RC type
Crystal type
PLL type
8-Bit Microcontroller
Bit 3
Bit 2
Bit 1
Bit 0
PR2
PR1
PR0
Sub Oscillator Type
RC type
RC type
RC type
Crystal type
Crystal type
Crystal type