Conversion Kit Instructions - kozy heat 936 Installation And Operation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

CONVERSION KIT INSTRUCTIONS

#OCK-S31A NAT GAS CONVERSION KIT
This conversion kit shall be installed by a qualified service agency in accordance
with the manufacturers instructions and all applicable codes and requirements of
the authority having jurisdiction. If the information in these instructions is not
followed exactly, a fire, explosion or productions of carbon monoxide may result,
causing property damage, personal injury or loss of life. The qualified service agency
WARNING
is responsible for proper installation of this kit. The installation is not proper and
complete until operation of the converted appliance is checked as specified in the
manufacturer's instructions supplied with the kit. Refer to appliance owner's
manual or product data plate for proper inlet and manifold pressure adjustments
and orifice sizing.
This kit includes:
(1) Valve Conversion Instructions
(1) Burner Orifice #31 NAT / #51 LP
(1) Pilot Orifice (BL22N-NAT / BL14LP-LP) (1) Pilot Conversion Instructions
CAUTION
THE GAS SUPPLY SHALL BE SHUT OFF PRIOR TO DISCONNECTING THE ELECTRICAL POWER, BEFORE PROCEEDING WITH
THE CONVERSION.
SHUT OFF GAS SUPPLY AND ELECTRIC POWER TO FIREPLACE.
SHUT OFF GAS SUPPLY BEFORE DISCONNECTING ELECTRIC POWER.
WARNING
For high altitude installations: Above 2000ft. (610m) US / 4500ft. (1372m) Canada, consult the local gas distributor or
IMPORTANT
authority having jurisdiction for proper de-rating methods.
PREPARE FIREPLACE:
1.
Turn fireplace off by pushing in and turning gas control knob clockwise to OFF position.
2.
Remove upper grill, glass frame assembly*, logs*, and burner assembly* from fireplace.
Figure 34a
CONVERT PILOT ASSEMBLY:
1.
Using a 7/16" wrench, loosen and remove pilot hood by turning counter-clockwise.
2.
Remove pilot orifice located inside pilot housing. Install pilot orifice included with kit. (Number stamped on pilot orifice)
NAT: BL22N / LP: BL14LP
3.
Re-attach pilot hood. Tighten with wrench, making sure hood is centered between thermopile and thermocouple.
REPLACE BURNER ORIFICE:
Remove existing orifice cap. Install orifice cap included with kit, making sure to tighten cap securely. (Number stamped on orifice).
NAT: #31 / LP: #51
CONVERT HI/LO REGULATOR ON GAS VALVE:
Follow instructions included with kit to convert gas valve.
/ #OCK-S51A LP GAS CONVERSION KIT
(1) Gas Pilot Injector
(1) Gas Label
NAT
LP
PILOT ORIFICE
34
(1) Gas Conversion Label

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-36