Installation Of The Wired Aqualink Touch Ac Adapter Kit In The Low-Voltage Raceway - Jandy AquaLink Touch Installation And Operation Manual

Wired/wireless controller
Hide thumbs Also See for AquaLink Touch:
Table of Contents

Advertisement

7.
Using the self-adhesive strip attached on the back
of the AC adapter, attach the AC adapter to the
power center.
8.
Secure the RS485 interface board and mounting
bracket to the daughter card mounting area in the
bezel assembly with two (2) self-tapping screws
provided in the kit. See Figure 8.
9.
Remove the red, 4-pin terminal bar from the power
center PCB and bezel assembly and secure each
of the four (4) color wires of the RS485 interface
board cable to their corresponding color into the
4-pin terminal bar. Reconnect the 4-pin terminal bar
to the power center PCB and bezel assembly.
AquaLink RS Transformer
24 VAC Power Plug
RS485 Interface
Board AC Adapter
Cable
Wired
AquaLink Touch
RS485 Cable
Bezel Assembly
AquaLink RS Daughter Card
Mounting Area
Figure 8.
Installation of the RS485 Interface Board
Assembly
AquaLink
Touch™ Installation and Operation Manual
®
AC Adapter
Self-Adhesive
Strip
Power Center PCB
and Bezel Assembly
RS485 Interface
Board Cable
4 3 2 1
4-Pin
Terminal Bar
Mounting Bracket
Self-Tapping
Screw (2)
10. Remove the red, 4-pin terminal bar from the
RS485 interface board and secure the AquaLink
Touch RS485 four (4) color cable to the red, 4-pin
terminal bar. Reconnect the 4-pin terminal bar to
the RS485 interface board.
11. Re-connect the AquaLink RS transformer 24 VAC
power plug to the 24 VAC 3-pin terminal on the
power center PCB and bezel assembly.
12. Reinstall the power center PCB and bezel assembly
in the power center can using the screws previously
removed.
3.3
Installation of the Wired AquaLink
Touch AC Adapter Kit in the Low-
Voltage Raceway
If the daughter card area is not available or if the slots
on the bezel assembly are all used, install the RS485
interface board in the low-voltage raceway of the power
center.
WARNING
Potentially high voltages in the AquaLink RS power
center can create dangerous electrical hazards,
possibly causing death, serious injury or property
damage. Turn off power at the main circuit feeding
the AquaLink RS power center to disconnect the
power center from the system.
1.
Turn off all power to the power center.
2.
Unscrew and remove the power center PCB and
bezel assembly from the power center.
3.
Unplug the AquaLink RS transformer 24 VAC
power plug from the 24 VAC 3-pin terminal on the
power center PCB and bezel assembly as shown in
Figure 8.
4.
Pull the white and black wires of the AC Adapter
into the high voltage area through the wire conduit.
The AC adapter and the power center
NOTE
transformer will share the breaker panel
terminals. See Figure 7.
5.
In the high voltage area of the power center,
connect the white and black wires to the AC power
source.
6.
Using the self-adhesive strip atached on the back of
the AC adapter, attach the AC adapter to the power
center.
Page 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents