Wired Surface-Mount Installation - Jandy AquaLink Touch Installation And Operation Manual

Wired/wireless controller
Hide thumbs Also See for AquaLink Touch:
Table of Contents

Advertisement

4.
To release the LCD front panel and PCB from the
AquaLink Touch case, use the provided tool to
press gently on the retaining tabs located on each
side of the panel.
Retain the tab release tool for future use.
NOTE
5.
Disconnect the wire harness from the RS485
interface board and pull the front panel out the
AquaLink Touch case.
6.
Depending on the thickness of the drywall,
determine which side of the cleat is to be facing.
For 1/2" (1,2 cm) use the small hook facing the
drywall. For 5/8" (1,5 cm) use the bigger hook
facing the drywall. See Figure 11.
Use this side against
drywall for 5/8"
(1,5 cm) thickness
Figure 11.
Installation of the Cleats
7.
Wire the 4-conductor cable to the red, 4-pin
terminal bar. Push the 4-pin terminal bar onto the
RS485 interface board at the back of the AquaLink
Touch case.
8.
As shown in Figure 10, insert the screws through
the tabs and put the cleats into the four (4) holes of
the AquaLink Touch case. Hand tighten the screws.
9.
Place the AquaLink Touch case on the wall and
connect the wire harness of the front panel to the
RS485 interface board. Place the LCD front panel
back into the case.
3.5

Wired Surface-Mount Installation

WARNING
Potentially high voltages in the AquaLink RS power
center can create dangerous electrical hazards,
possibly causing death, serious injury or property
damage. Turn off power at the main circuit feeding
the AquaLink RS power center to disconnect the
power center from the system.
AquaLink
Touch™ Installation and Operation Manual
®
Use this side against
drywall for 1/2"
(1,2 cm) thickness
See section 3.2 and 3.3 to install the AC adapter kit in
the power center.
1.
With the aid of the homeowner, fi nd the best
location for the AquaLink Touch controller.
2.
Place the surface mount bracket in the location
chosen. Mark the holes for drilling for the bracket.
3.
Drill two (2) holes for the anchors and a 1½" (4
cm) hole for the 4-conductor cable. See Figure 12.
4.
Install the two (2) anchors into the holes of the
wall.
5.
Secure the mounting bracket to the wall with the
two (2) self-tapping screws provided in the kit.
6.
Route the 4-conductor cable from the power center
to the AquaLink Touch controller.
7.
Pull the 4-conductor cable through the hole in the
wall. Wire the 4-conductor cable to the red, 4-pin
terminal bar located on the back of the AquaLink
Touch controller.
8.
Align the four (4) holes on the back of AquaLink
Touch controller and snap into the four (4) retainer
screws on the bracket.
Self Tapping
Screw (2)
4-Conductor
Cable
AquaLink Touch Controller
Figure 12.
Installation of the Wired Surface-Mount
AquaLink Touch Controller
Page 11
Wall
1 ½" Hole
Anchor (2)
Surface Mount
Bracket

Hide quick links: