Wired Flush-Mount Installation - Jandy AquaLink Touch Installation And Operation Manual

Wired/wireless controller
Hide thumbs Also See for AquaLink Touch:
Table of Contents

Advertisement

Page 10
7.
Secure the RS485 interface board and mounting
bracket inside of the power center can in the low
voltage raceway. See Figure 9.
8.
Remove the red, 4-pin terminal bar from the power
center PCB and bezel assembly and secure each
of the four (4) color wires of the RS485 interface
board cable to their corresponding color into the
4-pin terminal bar. Reconnect the 4-pin terminal bar
to the power center PCB and bezel assembly.
9.
Remove the red, 4-pin terminal bar from the
RS485 interface board and secure the AquaLink
Touch RS485 four (4) color cable to the red, 4-pin
terminal bar. Reconnect the 4-pin terminal bar to
the RS485 interface board.
10. Re-connect the AquaLink RS transformer 24 VAC
power plug to the 24 VAC 3-pin terminal on the
power center PCB and bezel assembly.
11. Reinstall the power center PCB and bezel assembly
in the power center can using the screws previously
removed.
5 4
7 6
9 8
1 0
2 1
4 3
6 5
2 1
4 3
2 1
4 3
RS485 Interface Board
AC Adapter Cable
Wired
AquaLink Touch
RS485 Cable
Figure 9.
Installation of the RS485 Interface Board in
the Low-Voltage Raceway
AquaLink
Touch™ and Operation Installation Manual
®
1
3 2
RS485 Interface
Board Cable
RS485 Interface Board
Assembly
3.4

Wired Flush-Mount Installation

WARNING
Potentially high voltages in the AquaLink RS power
center can create dangerous electrical hazards,
possibly causing death, serious injury or property
damage. Turn off power at the main circuit feeding
the AquaLink RS power center to disconnect the
power center from the system.
See section 3.2 and 3.3 to install the AC adapter kit in
the power center.
1.
With the aid of the homeowner, fi nd the best
location for the AquaLink Touch controller.
CAUTION
Prior to cutting any holes, ensure sufficient
clearance. Check for any hidden wires or structural
braces behind the wall where the panel is to be
located.
2.
Place the template in the location chosen. Level
the template and trace around the outside of the
box with a pencil. Cut the hole being careful not to
oversize.
3.
Route the 4-conductor cable from the power center
to the wall.
Cleat (4)
RS485 Interface
Screw (4)
Front Panel
Retaining
Tabs (2)
Wire Harness
Tab Release
Tool
Figure 10.
Installation of the Wired Flush-Mount
AquaLink Touch Controller
Mark this hole on drywall
with the provided template
Board
AquaLink Touch Case

Hide quick links:

Advertisement

Table of Contents
loading