Avoid upper body/top heavy bending. Do not lean forward or sideways whilst
handling the stove.
Always grip with the palm of the hand. Do not use the tips of fingers for support.
Always keep the stove as close to the body as possible. This will minimise the
cantilever action.
Use gloves to provide additional grip.
Always use assistance if required.
2. APPLIANCE DATA AND EFFICIENCY
General information.
Gas
Inlet Pressure
Input - Max. (Gross)
Input - Min. (Gross)
Inlet Test Pressure (Cold)
Gas Connection
Burner Injector
Pilot
Ignition
Aeration
*When converted using kit 0591011.
The appliance information label is located on a plate at the base of the stove.
Efficiency.
The efficiency of this appliance has been measured as specified in BS EN 613 and
the result is as below :
Model
910
910 when converted to LPG.
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Natural (G20)
20mbar
5.50kW (18,766Btu/h)
2.3kW (7,850 Btu/h)
20.0 ± 1.0mbar
(8.0 ± 0.4in w.g.)
8mm pipe
Cat 82 - 065
Copreci Ref. O.D.S
21500/212
Piezo Electric. Integral with
Gas Tap
See page 18
Page 6
Propane (G31) *
37mbar
5.4kW (18,425Btu/h)
3.8kW (12,965Btu/h)
37.0 ± 1.0mbar
(14.85 ± 0.4in w.g.)
8mm pipe
Size 116
Copreci Ref. O.D.S
21500/212 Fitted with RBM
180 -02 injector
Piezo Electric. Integral with
Gas Tap
Non-adjustable
Efficiency % (Gross)
73.1
73.1