Servicing - Baxi 910 Installer And Owner Manual

Cast-iron gas stove fitted with a ceramic coal fuel effect
Table of Contents

Advertisement

Explain to the customer that when operating the stove for the first time, some
vapours may be given off which may cause a slight odour and could possibly set off
any smoke alarms in the immediate vicinity. These vapours are quite normal with new
appliances. They are totally harmless and will disappear after approximately twelve
hours use.
Inform the customer that the Serial number for the appliance is located on
the metal plate attached to the burner at the bottom of the appliance
underneath the burner module.

Servicing.

This product uses fuel effect pieces containing Refractory Ceramic Fibres
(RCF), which are man-made vitreous silicate fibres. Excessive exposure to
these materials may cause irritation to eyes, skin and respiratory tract.
Consequently, it is important to take care when handling these articles to
ensure that the release of dust is kept to a minimum. To ensure that the release
of fibres from these RCF articles is kept to a minimum, during installation and
servicing we recommend that you use a HEPA filtered vacuum to remove any
dust and soot accumulated in and around the stove before and after working on
the stove. When replacing these articles we recommend that the replaced items
are not broken up, but are sealed within a heavy duty polythene bag, clearly
labelled as RCF waste. RCF waste is classed as a stable, non-reactive
hazardous waste and may be disposed at a landfill licensed to accept such
waste. Protective clothing is not required when handling these articles, but we
recommend you follow the normal hygiene rules of not smoking, eating or
drinking in the work area and always wash your hands before eating or
drinking. This appliance does not contain any component manufactured from
asbestos or asbestos related products.
Always turn off the gas supply and allow to cool completely before commencing
any servicing.
Check that the thermal switch is correctly located in the diverter box (See figure 4
on page 10).
Check that the appliance is clean and that no matter is blocking the burner or pilot
which may cause imperfect flames or prevent a correct electrode spark.
After servicing, make sure that the ceramic fuel effect pieces are replaced
correctly as described in the installer and owner guide supplied with the ceramic
fuel effect. The ceramic fuel effect guide may have been placed inside or attached to
this guide.
Always test for gas soundness and spillage after servicing the appliance.
©