Download Print this page

Safety; Appliance Data - Baxi 3226424 Installer's Manual

Cast-iron gas stove

Advertisement

PartsArena

1. SAFETY

Installer
Firefox stoves are efficient appliances giving off convected, conducted and radiated heat. All the surfaces of the stove - except
the controls - are working surfaces and become hot in use. They must not be touched or have any combustible objects or
materials placed on or near them. A fire guard complying with BS 8423 should be fitted for the protection of young children, the
elderly, the infirm or pet animals.
The appliance is fitted with a flue safety device. If the appliance closes down after a period of operation for no apparent reason,
the consumer should be informed to stop using the appliance until the installation and appliance have been thoroughly checked.
Under no circumstances should the flue safety device be altered or bypassed in any way. Only a genuine manufacturers
replacement part should be fitted.
Before continuing any further with the installation of this appliance please read the following guide to manual handling:
The lifting weight of this appliance is 55 kg. We therefore recommend that two people should be sufficient to lift the stove.
If fitting or moving the stove alone we recommend the use of suitable lifting apparatus.
When lifting always keep your back straight. Bend your legs and not your back.
Avoid twisting at the waist. It is better to reposition your feet.
Avoid upper body/top heavy bending. Do not lean forward or sideways whilst handling the stove.
Always grip with the palm of the hand. Do not use the tips of fingers for support.
Always keep the stove as close to the body as possible. This will minimise the cantilever action.
Use gloves to provide additional grip.
Always use assistance if required.
Page 3

2. APPLIANCE DATA

Gas
Inlet Pressure
Input - Max. (Gross)
Input - Min. (Gross)
Inlet Test Pressure (Cold)
Gas Connection
Burner Injector
Pilot
Ignition
Aeration
*When converted using kit 0591011.
The appliance information label is located on a plate at the base of the stove.
The efficiency of this appliance has been measured as specified in BS EN 613 and the result is as below :
Model
910
910 when converted to LPG.
The gross calorific value of the fuel has been used for this efficiency calculation. The test data from which it has been calculated
has been certified by Advantica Certification services (0087). The efficiency value may be used in the UK Government's
http://www.partsarena.com/baxi/[15/07/2008 11:36:43]
Natural (G20)
20mbar
5.50kW (18,766Btu/h)
2.3kW (7,850 Btu/h)
20.0 ± 1.0mbar (8.0 ± 0.4in w.g.)
8mm pipe
Cat 82 - 065
Copreci Ref. O.D.S 21500/212
Piezo Electric. Integral with Gas Tap
See
section 7.1
Propane (G31)
37mbar
5.4kW (18,425Btu/h)
3.8kW (12,965Btu/h)
37.0 ± 1.0 mbar (14.85 ± 0.4in w.g.)
8mm pipe
Size 116
Copreci Ref. O.D.S 21500/212 Fitted
with RBM 180 -02 injector
Piezo Electric. Integral with Gas Tap
Non-adjustable
Efficiency % (Gross)
73.1
73.1
*