Gas
Inlet Pressure
Input - Max. (Gross)
Input - Min. (Gross)
Inlet Test Pressure (Cold)
Gas Connection
Burner Injector
Pilot
Ignition
Aeration
*When converted using kit 0591011.
The appliance information label is located on a plate at the base of the stove.
The efficiency of this appliance has been measured as specified in BS EN 613 and
the result is as below :
Model
910
910 when converted to LPG.
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The conversion of net efficiency to gross was achieved by multiplying the net
efficiency by the following conversion factor from Table E3 of SAP 2005, rounding
down to the nearest whole number.
Gas
Natural Gas
LPG
©
Baxi Heating U.K. Limited 2007.
INSTALLER GUIDE

2. APPLIANCE DATA

Natural (G20)
20mbar
5.50kW (18,766Btu/h)
2.3kW (7,850 Btu/h)
20.0 ± 1.0mbar (8.0 ± 0.4in
w.g.)
8mm pipe
Cat 82 - 065
Copreci Ref. O.D.S
21500/212
Piezo Electric. Integral with
Gas Tap
See section 7.1
Conversion factor from net to gross efficiency
Page 4
Propane (G31) *
37mbar
5.4kW (18,425Btu/h)
3.8kW (12,965Btu/h)
37.0 ± 1.0 mbar (14.85 ±
0.4in w.g.)
8mm pipe
Size 116
Copreci Ref. O.D.S
21500/212 Fitted with RBM
180 -02 injector
Piezo Electric. Integral with
Gas Tap
Non-adjustable
Efficiency % (Gross)
0.901
0.921
73.1
73.1