Dvvk-4F Flex Vent Instructions - Empire Comfort Systems DVX36FP32CLN-2 Installation Instructions And Owner's Manual

Direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

The DVVK-4F FLEX VENT KIT includes the following components:
(1) Horizontal Termination Cap
(1) 4-foot section of Flex vent with spacers (4" flue/7" outer
pipe)
(1) 4" diameter flue adapter collar
Flex venting can only be installed vertically off of the DVX Series fireplaces. When installing a horizontal vent run from top connections,
maintain at least ½" rise for every 12" of vent run. Refer to Figure 54 when mounting termination near vinyl siding.
CAUTION: Always stretch and secure venting with wire or metal strapping to ensure that the horizontal runs do not sag.
If space permits, it is generally easier to attach venting in the top vent configuration.
Because of sharp edges, always use gloves when handling the flex vent components.
Vent connections should overlap a minimum of 1" for proper sealing.
Always follow the general venting requirements for vent terminal location, vent lengths, and clearance to combustible materials.
INSTALLATION
1.
Unpack vent components and check that all items are included.
2.
Check to see that the vent spacer springs are located around
the flue vent at 8" and 12" intervals along its length. See Figure
42. If not, stretch the spacer springs to about 15" long and wrap
them around the flue, then interlock the ends of each spring
about 2". See Figure 43. Maintain equal distance between spring
spacers.
FLEX OUTER VENT
3.
Remove the 6-⅝" diameter vent collar from the fireplace. Replace
this collar with the 7" diameter Flex Vent adapter collar provided
with the vent kit.
4.
Slide the Flex Vent flue pipe into the Outer Flex Vent pipe.
5.
Install the Wall Firestop/Thimble assembly as required through
the wall. Refer to the venting charts in the fireplace manual to
determine the proper height and size of the vent opening. The
minimum opening should be 9" wide by 11" high. The minimum
combustible clearance from the horizontal vent is 1" from sides
and bottom, and 3" above the vent pipe. See Figure 45.
6.
In most cases, after determining the length of the vent that is
needed, it may be easier to install the flue and outer vent pipes to
the Termination Cap first, then from the outside, feed the venting
through the wall to the fireplace.
7.
If the venting is to long, trim off any excess vent before attaching
the vent end connectors.
30329-0-0312
DVVK-4F FLEX VENT INSTRUCTIONS
SPACER
SPRINGS
FLEX FLUE PIPE
Figure 42
Figure 43
(1) 7" diameter outer vent adapter collar
(1) Wall Firestop/Thimble Assembly
Hardware pack that includes band clamps and screws
8.
Attach the Termination Cap to the outside of the house.
9.
Prior to making the vent connections, apply high temperature
sealant (1000 degree F min.) to the vent connections before
securing with the band clamps provided. Note: The flue pipe end
without the adapter is to be installed to the Termination Cap.
10. Apply sealant to the outside of the flue pipe adapter and connect
to the flex flue pipe. Then insert the adapter into the fireplace flue.
Secure flue adapter to the fireplace flue with a minimum of two
screws provided. See Figure 44.
11. Attach the Outer Vent pipe to the 7" diameter collar on the fireplace
with a large band clamp provided. Sealant may also be used on
the outer vent connections.
12. Check all vent connections for tightness. Make sure horizontal
venting has the proper rise and combustible clearances required.
Refer to venting charts in fireplace instruction manual.
7" DIA. FLEX
VENT PIPE
4" DIA. FLEX
FLUE PIPE
4" DIA. FLUE
ADAPTOR
COLLAR
7" DIA. INLET
ADAPTOR COLLAR
(WITH GASKET)
BAND CLAMP
APPLY HIGH
TEMPERATURE
SEALANT
Figure 44
Figure 45
Page 29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents