10-6. Checking and Troubleshooting when the Front Panel fails to work

10-6-1. Checking the Front Panel when it fails to work during operation
(1) Is the grille mounted in place?
(Check in particular that the upper right screw is
adequately tightened.)
(2) Are the five levers on the rear of the front panel
tightened?
The figure shows the loosened condition.
If the levers are in loosen, the front panel does
not work correctly.
(3) Is the front panel correctly mounted?
1.
Holding the part of the front panel adjacent to the arm.
Next, press the arm shaft against the upper part of the
groove which is located on the main body while
keeping the front panel almost horizontally, and push
it firmly until it makes a sound of being seated.
Groove
Arm shaft
Arm
Front panel
(which is attached with a sub-panel on its rear side)
Grille
Screw
Lever
Loosen
Tighten
Groove
Arm shaft
Arm
49
Upper right screw
Flap
Screw cover
Front panel
Sub-panel
Lever
Loosen
Tighten
2.
Close the front panel, and
push at the arrow to firmly fix it.